Most lighting designers still specify by lux and CCT. Here is why the melanopic-to-photopic ratio is the single number that determines whether a space supports or disrupts circadian health.

The M/P ratio is the melanopic-to-photopic ratio: how much circadian-weighted light a source delivers for each unit of visual brightness. It is the single number that lets you compare a 2700 K warm white against a 5700 K daylight white at the same lux. It is also a ratio, not a measurement, and this article shows exactly where it helps and where it stops being useful.
Terms and units (six definitions, one table)
| Term | Symbol / unit | What it is | Who defines it |
|---|---|---|---|
| Photopic illuminance | lux (lx) | Light weighted to human daytime vision, V(λ). What a lux meter reports. | CIE S 026:2018 (conventional) |
| Melanopic EDI | m-EDI, melanopic lx, in lx | The illuminance of a D65 daylight source that would produce the same melanopic irradiance as the light being measured. | CIE S 026:2018 |
| Equivalent Melanopic Lux | EML | The same quantity under WELL's earlier naming, using a different normalisation. | WELL v2 / WELL Building Standard |
| M/P ratio | M/P, melanopic DER | Melanopic EDI divided by photopic illuminance for the same source and condition. Dimensionless. | CIE S 026:2018 (as melanopic DER) |
| Melanopic DER | DER = M/P | Daytime Equivalent Ratio — the standards name for M/P. | CIE S 026:2018 |
| Melanopic irradiance | W/m², melanopic | Absolute melanopic power at the eye, before normalisation. What a spectroradiometer actually reads. | CIE S 026:2018 |
Source: CIE S 026:2018 (metric definitions). Unit names verified against the WELL v2 Feature L03 text; the standard's own full text was not read.
Take a white light source, measure its spectral power distribution, weight that SPD twice — once with the photopic luminosity function V(λ), once with the melanopic action spectrum — and divide the second result by the first. The number you get is the M/P ratio, which CIE S 026:2018 calls the melanopic daylight efficacy ratio (melanopic DER).
Because it is a ratio, M/P has no units and no illuminance in it. A 2700 K source at 200 lx and the same 2700 K source at 800 lx have the same M/P ratio. That is the point: M/P describes spectrum, while lux describes quantity. Together they give the absolute melanopic dose — which is the number that actually matters.
The reaction `m-EDI ≈ lux × M/P` is the working relation. At 500 lx, a source with M/P 0.45 delivers about 225 melanopic EDI; a source with M/P 0.92 delivers about 460. Same brightness, twice the circadian signal. This is why a spec sheet that lists only lux, CCT and CRI cannot tell you whether a light will do anything circadian at all.
Source: definitional (CIE S 026:2018 metric definitions); the arithmetic relation m-EDI = lux × M/P is internal (SUMLINK internal estimate).
M/P is not constant across a tunable-white fixture's range, and it is not linear either. Warm white has very little short-wavelength energy, so it carries little circadian signal; as you shift toward daylight white, melanopic content climbs faster than photopic content.
| CCT | M/P ratio | m-EDI at 500 lx | Role in a schedule |
|---|---|---|---|
| 2700 K | 0.45 | 225 | Deep warm. Melanopic minimum — evening and late-service setting. Clears WELL tier 1 (136 m-EDI); below tier 2 (250 m-EDI). |
| 3000 K | 0.51 | 255 | Residential warm white. Clears tier 1 and, at 255 m-EDI, sits just above tier 2 (250 m-EDI). |
| 3500 K | 0.58 | 290 | First step with comfortable margin over tier 2 (290 m-EDI at 500 lx). |
| 4000 K | 0.66 | 330 | Neutral reference point. Colour metrics stated at 4000 K. |
| 5000 K | 0.81 | 405 | Alerting daylight white for morning ramp-up and task-dense hours. |
| 5700 K | 0.92 | 460 | High circadian stimulus; typical mid-morning peak. |
| 6500 K | 1.06 | 530 | Maximum melanopic output. Use in short bursts, not all day. |
Source: BY001 catalogue page, melanopic DER table (all values labelled Design target). Internal consistency check: 500 lx × M/P reproduces every m-EDI figure exactly.
Two things to notice. First, read the two WELL tiers separately, because they cross at very different points. Tier 1 (150 EML = 136 m-EDI) is cleared by every row in the table at 500 lx — even the warmest, 2700 K at 225 m-EDI, sits well above it. Tier 2 (275 EML = 250 m-EDI) is the demanding one: the 3000 K row at 255 m-EDI is the first step that clears it, with the 3500 K row at 290 m-EDI the first to clear it with real margin. Second, the ratio between the warmest and coolest setting is 2.4× in M/P (1.06 / 0.45). A tunable-white system that can only make a small spectral shift will never move the circadian needle very far, no matter how wide its CCT marketing claim is.
One source defect worth flagging: the live BY001 page annotates its 3000 K row "below the WELL daytime threshold" and its 3500 K row as the first step that clears it. Neither annotation is consistent with either published WELL tier in its stated unit — 3000 K clears tier 2 (255 > 250 m-EDI), and every row clears tier 1. The annotations are only self-consistent if the threshold is read as 275 m-EDI rather than 275 EML — the unit mix-up this article exists to correct. The table above resolves it the defensible way; the catalogue page should be amended to match.
Most confusion around M/P comes from mixing up three separate questions: what the target is in the morning, during the day, and in the evening. They come from different sources, and only one of them is a certification threshold.
| Band | Time window | Target | Who set it | Checkable path |
|---|---|---|---|---|
| Morning activation | First ~2–3 h of occupancy | M/P ≥ 0.90 at working illuminance; equivalently m-EDI ≥ 250 lx at the eye | Research recommendation, not a certification | Brown et al. 2022, PLoS Biology 20(3): e3001571 — daytime minimum 250 melanopic EDI at the eye, vertical plane, ~1.2 m |
| Daytime | Core occupied hours | WELL v2 L03 tier 1: ≥150 EML (136 m-EDI); tier 2: ≥275 EML (250 m-EDI), for at least 4 h | WELL Building Standard v2, Light concept, Feature L03 | the WELL v2 Feature L03 page (2026-10-01 capture of the live feature text) |
| Evening / pre-sleep | Last ~2–3 h, and ≥3 h before bedtime | Melanopic EDI ≤ 10 lx at the eye; as a procurement proxy, warmest preset at minimum illuminance | Research recommendation | Brown et al. 2022 — evening maximum 10 melanopic EDI at the eye |

Note on the evening row, and a correction to previous copy on this site: our own warmest platform setting is 2700 K, which measures M/P 0.45. That is above the M/P 0.40 figure some briefs quote as an evening cap, so an evening target written as "M/P < 0.40" cannot be met by colour temperature alone on this platform. It is met by dropping illuminance — 10 melanopic EDI at the eye is reached by dimming, not by pushing the spectrum warmer than 2700 K. Any tender clause that demands both M/P < 0.40 and a 2700 K minimum is internally inconsistent and should be rewritten as an m-EDI-at-the-eye cap.
This table is the article in one screen. Both columns are the same measured illuminance at the same working plane. The only difference is the spectrum.
| Source type | M/P ratio | m-EDI at 500 lx | Passes WELL v2 L03 tier 1 (136 m-EDI)? |
|---|---|---|---|
| Warm-white LED, narrow short-wavelength output | 0.30 | 150 | Yes, marginally |
| 2700 K tunable white, warmest preset | 0.45 | 225 | Yes |
| 4000 K neutral tunable white | 0.66 | 330 | Yes |
| 5700 K daylight white | 0.92 | 460 | Yes, comfortably |
| Full-spectrum source, daylight-like SPD | 0.90 | 450 | Yes, comfortably |

Source: rows 2–4 from the BY001 design-target curve; rows 1 and 5 are worked examples at M/P 0.30 and 0.90 (SUMLINK internal estimate, chosen to bracket the range a specifier is likely to meet in the market). The point of the table is arithmetic, not measurement.
Read it as a warning against a common procurement error: a brief that specifies "500 lux, CRI 90" and stops there can be satisfied by a source that delivers only 150 m-EDI — technically compliant, circadianly inert. The engineering response is not necessarily a higher illuminance. It is a spectrum with more melanopic content at the same lux, which is exactly what M/P quantifies.
Here is a six-node schedule from the office program, translated from colour temperature into melanopic terms. The m-EDI column is obtained by scaling the 500 lx design curve linearly with illuminance — it is an internal calculation, not a laboratory measurement, and it is the method a specifier should use to model a schedule before commissioning.
| Time | CCT | Illuminance | M/P | m-EDI (calculated) | Band |
|---|---|---|---|---|---|
| 08:00 | 5700 K | 500 lx | 0.92 | 460 | Morning activation |
| 09:30 | 5000 K | 480 lx | 0.81 | 389 | Morning activation |
| 12:00 | 4500 K | 450 lx | 0.74 | 331 | Daytime |
| 14:00 | 4000 K | 420 lx | 0.66 | 277 | Daytime |
| 17:00 | 3500 K | 350 lx | 0.58 | 203 | Daytime, wind-down |
| 18:30 | 2700 K | 250 lx | 0.45 | 112 | Evening transition |
Source: schedule nodes from the live office program (`/lighting-programs`); M/P values interpolated from the BY001 design-target curve (4500 K = linear interpolation between 4000 K and 5000 K = 0.74); m-EDI = illuminance × M/P, internal calculation.
The schedule shows where the useful work happens. Between 08:00 and 14:00 the system holds melanopic EDI above the WELL tier-1 threshold and above the 250 m-EDI research minimum for the first 90 minutes. By 18:30 it is at 112 m-EDI — which is low, but still an order of magnitude above the 10 m-EDI research recommendation for the pre-sleep window. The evening band cannot be reached by this schedule while the office is still lit to 250 lx. Getting to research-level evening exposure requires dropping illuminance to roughly 20–25 lx at the eye, which is a different design decision (task lighting, or simply turning the main run off) rather than a colour-temperature setting.
That is the practical lesson: M/P tells you about the spectrum you specify, and m-EDI tells you what the occupant actually receives. You need both columns in a specification. If a supplier gives you only one, you cannot model the schedule.
M/P is a scalar summary of an entire spectral power distribution. That compression is useful and also lossy. Four limitations matter in practice:
Source: limitations 1–2 and 4 are properties of the metrics as defined in CIE S 026:2018; limitation 3 and the timing emphasis follow Brown et al. 2022.
The most-cited consensus recommendation for indoor exposure is Brown et al. (2022), written after the Second International Workshop on Circadian and Neurophysiological Photometry. It is a research recommendation, not a standard, and it is stated at the eye:
| Window | Recommendation | Measurement condition |
|---|---|---|
| Daytime (throughout) | Melanopic EDI ≥ 250 lx (minimum) | Vertical plane at the eye, ~1.2 m height, seated |
| Evening (starting ≥3 h before bedtime) | Melanopic EDI ≤ 10 lx (maximum) | As above |
| Night (sleep environment) | Melanopic EDI < 1 lx ambient; ≤10 lx where activity requires vision | As above |
Source: Brown TM, Brainard GC, Cajochen C, Czeisler CA, Hanifin JP, Lockley SW, et al. (2022). Recommendations for daytime, evening, and nighttime indoor light exposure to best support physiology, sleep, and wakefulness in healthy adults. PLOS Biology 20(3): e3001571. doi:10.1371/journal.pbio.3001571. Source checked 2026-10-02 via the publisher's article page.
Read against the table above, this is why the morning band targets M/P ≥ 0.90 at working illuminance. It is also why the evening band is a dimming problem, not a colour problem: 10 melanopic EDI at the eye is roughly what a 2700 K, M/P 0.45 source delivers at about 22 lx. No tunable-white fixture reaches it at office illuminance.
Every figure in this article taken from our own platform is labelled Design target. On our catalogue pages that label has a specific meaning: the value is an engineering design value derived from the LED and driver platform specification. It is not a laboratory report. Where a value is backed by a test report, the catalogue says so and the report is available on request.
We state this distinction because the alternative — a badge that implies third-party certification without a named laboratory and a report number — is not something a specifier can act on. If you are writing a tender, the clause you want is not "supplier-verified" but "a test report from an accredited laboratory, naming the instrument and the measurement geometry, delivered with the BOM." Ask for that, and the M/P number stops being a marketing claim.
Source: SUMLINK catalogue policy — `Design target` vs. test-report-backed values, as published on the BY001 page.
Yes. CIE S 026:2018 calls the quantity the melanopic daylight efficacy ratio (melanopic DER). M/P is the industry shorthand for the same division: melanopic EDI divided by photopic illuminance.
It depends on the band. For morning activation, M/P 0.90 or higher at working illuminance. For core daytime, enough to hold WELL v2 L03 (at least 150 EML, or 136 melanopic EDI) for at least four hours. For the evening, stop thinking in M/P and write a melanopic EDI cap at the eye instead, because 10 melanopic EDI is reached by dimming rather than by spectrum.
Partly. Melanopic EDI is the product of illuminance and M/P, so a spectrum with higher M/P delivers more circadian signal at the same lux. But the recommendations are written as an absolute melanopic EDI floor, so a dim room with a very cool source can still fall short.
Yes. The same spectral quality that supports alertness in the morning delays sleep onset in the evening. That is why a tunable system is worth specifying: it lets one installation serve both bands.
Values published as Design target are engineering values from the LED and driver platform specification, not independent laboratory results. Where a value is test-report backed, the catalogue page says so and we supply the report with the BOM on request.
Send us a room schedule and we will return it in melanopic terms. We will convert your existing illuminance plan into M/P and m-EDI per time node, flag any band that misses its target, and issue the per-SKU specification sheets for the fixtures that close the gap. → Request a room-by-room M/P schedule (`/science`)